<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://scemsprotocols.com/scems/index.php?action=history&amp;feed=atom&amp;title=Venous_Lactate_Monitoring_Procedure</id>
	<title>Venous Lactate Monitoring Procedure - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://scemsprotocols.com/scems/index.php?action=history&amp;feed=atom&amp;title=Venous_Lactate_Monitoring_Procedure"/>
	<link rel="alternate" type="text/html" href="https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;action=history"/>
	<updated>2026-04-05T06:35:00Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.0</generator>
	<entry>
		<id>https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;diff=1062&amp;oldid=prev</id>
		<title>Treloars at 17:48, 1 February 2018</title>
		<link rel="alternate" type="text/html" href="https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;diff=1062&amp;oldid=prev"/>
		<updated>2018-02-01T17:48:06Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 17:48, 1 February 2018&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l34&quot;&gt;Line 34:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 34:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;** Levels equal to or greater than 4 mmol/L are considered positive findings for metabolic distress and hypoperfusion.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;** Levels equal to or greater than 4 mmol/L are considered positive findings for metabolic distress and hypoperfusion.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The monitor must be checked with the “check strip” at least monthly or anytime there is a concern regarding the proper operation of the unit. It is suggested the check strip procedure to be completed the first Sunday of each month.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* The monitor must be checked with the “check strip” at least monthly or anytime there is a concern regarding the proper operation of the unit. It is suggested the check strip procedure to be completed the first Sunday of each month.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[Category:Procedure Guidelines|0933]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Treloars</name></author>
	</entry>
	<entry>
		<id>https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;diff=460&amp;oldid=prev</id>
		<title>Treloars: /* Procedure Guidelines */</title>
		<link rel="alternate" type="text/html" href="https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;diff=460&amp;oldid=prev"/>
		<updated>2012-05-23T20:04:38Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;Procedure Guidelines&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 20:04, 23 May 2012&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l19&quot;&gt;Line 19:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 19:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====PROCEDURE:====&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;====PROCEDURE:====&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Please refer to the device’s USER MANUAL for more detailed procedures specific to the monitor being used by your agency. The procedure below is generic for the Lactate Pro® monitors.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Please refer to the device’s USER MANUAL for more detailed procedures specific to the monitor being used by your agency. The procedure below is generic for the Lactate Pro® monitors.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The patient’s finger &lt;/del&gt;is &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;prepped in the usual fashion (&lt;/del&gt;alcohol &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;prep or betadine)&lt;/del&gt;, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;cleansed and allowed &lt;/del&gt;to &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;dry&lt;/del&gt;. &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The area must be completely &lt;/del&gt;dry before &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;lancing&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039;Do not use alcohol to clean the site unless it &lt;/ins&gt;is &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;extremely dirty.  If &lt;/ins&gt;alcohol &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;is used allow it to completely dry prior to testing&lt;/ins&gt;, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;failure &lt;/ins&gt;to &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;do so will cause incorrect readings&lt;/ins&gt;.&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* If the patient&#039;s hands are sweaty, &lt;/ins&gt;dry &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;with gauze &lt;/ins&gt;before &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;testing, sweat will cause incorrect readings.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* Do not use blood from an IV site or if an IV tourniquet is on the patients arm.  This will cause a high reading&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Place a new test strip (green in color) into the Lactate Pro® monitor by opening the foil and inserting the strip into the device. Be careful not to touch the strip.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Place a new test strip (green in color) into the Lactate Pro® monitor by opening the foil and inserting the strip into the device. Be careful not to touch the strip.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;** Use the test strip immediately after opening it. If left open to air for a long period of time (greater than 5 minutes) discard and use a new test strip.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;** Use the test strip immediately after opening it. If left open to air for a long period of time (greater than 5 minutes) discard and use a new test strip.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Treloars</name></author>
	</entry>
	<entry>
		<id>https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;diff=446&amp;oldid=prev</id>
		<title>Treloars: Created page with &quot;==Procedure Guidelines== ===9.33 Venous Lactate Monitoring Procedure===  ====DEFINITION:==== * The Venous Lactate Monitoring Procedure is indicated when a patient is suspected...&quot;</title>
		<link rel="alternate" type="text/html" href="https://scemsprotocols.com/scems/index.php?title=Venous_Lactate_Monitoring_Procedure&amp;diff=446&amp;oldid=prev"/>
		<updated>2012-05-10T14:14:46Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;==Procedure Guidelines== ===9.33 Venous Lactate Monitoring Procedure===  ====DEFINITION:==== * The Venous Lactate Monitoring Procedure is indicated when a patient is suspected...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;==Procedure Guidelines==&lt;br /&gt;
===9.33 Venous Lactate Monitoring Procedure===&lt;br /&gt;
&lt;br /&gt;
====DEFINITION:====&lt;br /&gt;
* The Venous Lactate Monitoring Procedure is indicated when a patient is suspected of sepsis or other medical condition that causes hypoperfusion of vital organs or there is a concern the patient is suffering from metabolic distress in shock or end-organ failure.&lt;br /&gt;
* It helps confirm cryptic shock.&lt;br /&gt;
&lt;br /&gt;
====INDICATIONS:====&lt;br /&gt;
* Patients presenting with signs and symptoms consistent of sepsis, have had a sepsis screening checklist completed with two or more positive major criteria and two or more positive minor criteria identified.&lt;br /&gt;
&lt;br /&gt;
====CONTRAINDICATIONS:====&lt;br /&gt;
* On patients with impending shock, suspected sepsis or end-organ failure, there are no contraindications for this procedure.&lt;br /&gt;
&lt;br /&gt;
====COMPLICATIONS:====&lt;br /&gt;
* Prolonged bleeding from the blood draw site.&lt;br /&gt;
* Pain from the lancing procedure.&lt;br /&gt;
* Infection.&lt;br /&gt;
&lt;br /&gt;
====PROCEDURE:====&lt;br /&gt;
* Please refer to the device’s USER MANUAL for more detailed procedures specific to the monitor being used by your agency. The procedure below is generic for the Lactate Pro® monitors.&lt;br /&gt;
* The patient’s finger is prepped in the usual fashion (alcohol prep or betadine), cleansed and allowed to dry. The area must be completely dry before lancing.&lt;br /&gt;
* Place a new test strip (green in color) into the Lactate Pro® monitor by opening the foil and inserting the strip into the device. Be careful not to touch the strip.&lt;br /&gt;
** Use the test strip immediately after opening it. If left open to air for a long period of time (greater than 5 minutes) discard and use a new test strip.&lt;br /&gt;
* The monitor will display the calibration number (usually an F-0 through F-12 number) before it is ready to accept a sample. This number must match the one of the strip being used. If the strip is inserted and a sample not placed into the strip within three (3) minutes, the monitor will turn off automatically.&lt;br /&gt;
* Lance the finger using a safety type lancing device.&lt;br /&gt;
* Press to obtain the first drop of blood from the site. DISCARD the first drop.&lt;br /&gt;
* Use the second drop obtained to complete the test. Put the tip or end of the strip against the drop of blood.&lt;br /&gt;
** The strip using a wicking effect will draw the blood sample into the strip. When enough blood is drawn, the monitor will make a beep sound.&lt;br /&gt;
** It takes 60 seconds to obtain a reading. The monitor will show a time countdown until the test is completed.&lt;br /&gt;
** If not enough blood is placed in the strip, the machine will not beep and/or run the test. Remove the strip, place a new one and repeat the test making sure enough blood is used and drawn until the beep sound is heard.&lt;br /&gt;
** The monitor will display “LO” if the venous lactate level is below 0.8 mmol/L and “HI” if the level is above 23.3 mmol/L. If this is the case, please repeat the test. Note in the incident record the results for both procedures.&lt;br /&gt;
** Levels equal to or greater than 4 mmol/L are considered positive findings for metabolic distress and hypoperfusion.&lt;br /&gt;
* The monitor must be checked with the “check strip” at least monthly or anytime there is a concern regarding the proper operation of the unit. It is suggested the check strip procedure to be completed the first Sunday of each month.&lt;/div&gt;</summary>